FCT18-X Multifunction Time Relay
Advanced Timing Functions for Industrial Control Systems
Product Overview
The FCT18-X represents the pinnacle of precision timing technology, engineered for the most demanding industrial environments. This compact 18mm module integrates 10 specialized timing functions with advanced triggering capabilities, delivering unparalleled flexibility for automation systems across manufacturing, process control, and building management applications.
Key Advantages
10 Timing Functions
Comprehensive timing operations including On-Delay, Interval, Flashing, Pulse Delay and more
Button Setting & Locking
Precision time setting via tactile buttons with locking protection to prevent accidental changes.
Extensive Timing Range
Supports timing from 0.1 seconds to 100 days for all functions
Flexible Triggering
Multiple trigger options with NPN/PNP control signals
Wide Voltage Input
Operates with 12-240V AC/DC, compatible with global power standards
Output Configuration
Available with 1 or 2 sets of 16A C/O contacts
Compact Design
Ultra-slim form factor with a width of just 18mm
Industrial Durability
High resistance to EMI, vibration, and temperature extremes
10 Timing Functions
The FCT18-X offers comprehensive timing solutions with 10 distinct functions. Select a function to view its detailed operation:
Ak: On-Delay with Control Signal
Sequence:
- Control signal(S) applied – timing starts
- After preset time (T) – output (R) closes
- Output (R) remains closed till control signal(S) is removed
Ck: Symmetrical Flashing (Starting Off)
Sequence:
- Control signal(S) applied – output (R) starts in open state
- After preset time (T) – output switches to closed state
- After preset time (T) – output switches to open state
- Cycle continues while Control signal(S) is present
Dk: Symmetrical Flashing (Starting On)
Sequence:
- Control signal(S) applied – output (R) starts in closed state
- After preset time (T) – output switches to open state
- After preset time (T) – output switches to closed state
- Cycle continues while Control signal(S)t is present
Je: Pulse After Delay
Sequence:
- Control signal(S) applied – timing starts
- After preset time (T) – output closes
- Output(R) remains closed for preset time (T)
- After time T – output(R) opens
- Output(R) remains open until next control signal
L: Alternating On/Off Delay
Sequence:
- First control signal(S): on-delay starts, output(R) closes after T
- Second control signal(S): off-delay starts, output(R) opens after T
- Subsequent control signals alternate between on-delay and off-delay
- Control signal will be invalid during timing
Q: Repeating Interval with Reset
Sequence:
- The first control signal(S) applied: output(R) closes immediately, then opens after preset time (T)
- when first control signal(S) removed: output(R) closes immediately, then opens after preset time (T)
- The following control signals applied: output closes immediately, then opens after 2T
- Control signal will be invalid during timing
Gr: On-Delay with Signal Ignore
Sequence:
- Control signal(S) applied –timing starts
- After preset time (T) – output(R) closes
- Output remains closed until next control signal(S) applied
- Control signal will be invalid during timing
As: On-Delay with Control Signal
Sequence:
- Control signal(S) applied –timing starts
- After preset time (T) – output(R) closes
- Output remains closed until next control signal(S) applied
- If control signal(S) reapplied timing T – timer resets
A: Power On-Delay
Sequence:
- Power(Un) applied – timing starts
- After preset time (T) – output (R) closes
- Output (R) remains closed while power is present
- Output (R) opens immediately when power is removed
B: Interval
Sequence:
- Power(Un) applied – output (R) closes immediately
- Timing starts simultaneously
- After preset time (T) – output(R) opens
- Output (R) remains open while power is present
Multifunction Timing Diagram
This diagram illustrates the various timing sequences available with the FCT18-X relay.
Sequences shown: On-Delay (A, Ak, As), Interval (B), Cyclic Timing (Ck, Dk), and Pulse Delayed (Je).
Function Selection & Time Setting
Function Selection:
Press the button to choose between the 10 timing functions (Ak, Ck, Dk, Je, L, Q, Gr, As, A, B).
Time Setting: Use the buttons to set timing and ratio parameters for each function.
Lock Function: Press and hold SET for 3 seconds to activate lock mode.
Wiring Diagram
Connection Guide:
Standard wiring for all timing functions. Terminal functions:
A1/A2: Power supply (12-240V AC/DC)
S: Control signal input
11/14/12 & 21/24/22: Output contacts (C/O)
Technical Specifications
| Parameter | FCT18-X1 | FCT18-X2 |
|---|---|---|
| Operating Functions | 10 timing functions | |
| Input terminal | A1-A2 | |
| Voltage range | AC230V / DC24V / ACDC12-240V | |
| Voltage tolerance | -15% ~ +10% | |
| Output type | 1 C/O contact | 2 C/O contacts |
| Rated current | 1×16A | 2×16A |
| Timing range | 0.1 sec – 100 days | |
| Time delay setting accuracy | ±0.1% of full-scale value | |
| Repeat accuracy | Δt < ±0.5% | |
| Temperature coefficient | Δt < 0.06 % / °C | |
| Mechanical life | 1×107 operations | |
| Electrical life | 1×105 operations | |
| Ambient temperature | -20°C to +60°C | |
| Mounting | DIN rail EN/IEC 60715 | |
| IP rating | IP20 | |
| Dimensions | 90×18×64mm | |
| Weight | Approx. 95g | |
| Standards | IEC60947-5-1, EN60947-5-1, UL508 | |
Get Technical Support
Contact our engineering team for application assistance