FCT18-Ata

on-delay relay with summation control signal
FCT18-Ata
Products Categories
Get a quote
FCT18-Ata | On-Delay Time Relay with Summation Control | Fiicco Electrical

FCT18-Ata On-Delay Relay with Summation Control

Accumulative Timing Control with Retrigger/Restart Functionality

Model: FCT18-Ata Series | DIN Rail Mount

Product Overview

The FCT18-Ata is a specialized on-delay relay with summation control signal functionality. Engineered for industrial automation systems requiring accumulative timing, it provides precise control where timing only accumulates during signal presence. With its compact 18mm DIN rail design and wide operating voltage range (12-240V AC/DC), the FCT18-Ata is the optimal solution for applications requiring intermittent timing accumulation with high precision (±0.1%).

Key Technical Advantages

Universal Voltage Input

Operates with 12-240V AC/DC, compatible with global industrial power standards.

Extensive Timing Range

Precise timing from 0.1 seconds to 100 days for diverse industrial applications.

Ultra-Compact Design

Space-saving 18mm width (90×18×64mm) for high-density control panels.

Exceptional Accuracy

Repeat accuracy ∆< ±0.5% and Time setting accuracy ∆< ±0.1%.

Industrial Robustness

Designed for -20°C to +60°C environments with EMI resistance.

Summation Control

Accumulates time only during signal presence for intermittent processes.

High-Capacity Output

16A C/O contacts (1 or 2 sets) for industrial loads.

Button Setting & Locking

Precision time setting via tactile buttons with locking protection to prevent accidental changes.

Industrial Application Scenarios

The FCT18-Ata relay with summation control excels in scenarios requiring accumulative timing only during signal presence. Below are key applications where its unique functionality delivers superior performance:

Production Line Cycle Counting

Tracks cumulative operational time of machines only when active, enabling precise maintenance scheduling based on actual usage rather than calendar time.

Key Benefits:

  • Accurate maintenance scheduling based on actual usage
  • Prevents unnecessary downtime
  • Reduces maintenance costs

Energy Usage Monitoring

Accumulates active time for energy-intensive equipment to calculate and optimize energy consumption patterns.

Key Benefits:

  • Precise energy usage tracking
  • Identifies inefficient equipment operation
  • Enables targeted energy-saving measures

Irrigation System Control

Accumulates watering time across multiple cycles to ensure plants receive precise hydration regardless of intermittent operation.

Key Benefits:

  • Optimized water usage
  • Precise irrigation control
  • Adapts to scheduled watering cycles

Batch Processing

Controls cumulative heating/cooling time for materials processed in multiple stages with intermittent operation.

Key Benefits:

  • Ensures consistent product quality
  • Accurate process timing across interruptions
  • Reduces material waste

Equipment Life Tracking

Monitors cumulative operational hours for critical machinery to predict maintenance needs and prevent failures.

Key Benefits:

  • Predictive maintenance scheduling
  • Extended equipment lifespan
  • Reduced unexpected downtime

Ventilation Control

Ensures cumulative ventilation time is met in environments with intermittent occupancy signals.

Key Benefits:

  • Maintains air quality standards
  • Energy-efficient operation
  • Complies with safety regulations

Timing Sequence

fct18-ata-function-diagram

Timing Operation:

Control signal (S) applied – accumulation starts

Control signal (S) removed – accumulation pauses

When accumulated time reaches preset time (T) – output closes

Wiring

fct18-ata-wiring-diagram

Connection Guide:

Standard DIN rail mounting with screw terminals for secure industrial connections:

  • A1/A2: Power supply terminals
  • S: Control signal input
  • 11/12/14 & 21/22/24: Output contacts (C/O)

Parameter Setting

time-setting-diagram

Time Adjustment Protocol:

1
To set new parameters, press and hold the button until the LED starts flashing.
2
Adjust the parameters to desired values via the button.
3
Press and hold the button until the LED stops flashing.
4
For the newly set parameters to take effect, you need to power off the device and then restart it.

Technical Specifications

Parameter FCT18-Ata1 FCT18-Ata2
Input terminal A1-A2
Voltage range AC230V / DC24V / ACDC12-240V
Voltage tolerance -15% ~ +10%
Output type 1 C/O contact 2 C/O contacts
Rated current 1×16A 2×16A
Power consumption AC 3.5VA / DC 2.0W
Time delay setting accuracy ±0.1% of full-scale value
Repeat accuracy Δt < ±0.5%
Mechanical life 10 million operations
Electrical life 100,000 operations
Ambient temperature -20°C to +60°C
Mounting DIN rail EN/IEC 60715
IP rating IP20
Dimensions 90×18×64mm
Standards IEC60947-5-1, EN6812-1
IEC 60947-5-1 Compliant
CE Certified
RoHS Compliant
IP20 Protection

Get Technical Support

Contact our engineering team for application assistance

fct18-ata-naming-convention

                CE                                                  Rohs                                                   EAC

Get A Quote