FCT18-AdR

Pulse delayed relay (single cycle) with control signal
FCT18-AdR
Products Categories
Get a quote
FCT18-AdR | On-Delay Time Relay with Retrigger Control | Fiicco Electrical

FCT18-AdR Industrial On-Delay Relay

Precision Timing Control with Retrigger/Restart Functionality

Model: FCT18-AdR Series | DIN Rail Mount

Product Overview

The FCT18-AdR is a high-precision on-delay relay with retrigger/restart control signal functionality. Engineered for complex industrial automation systems, it provides advanced timing control with dual timing sequences (T1 and T2) and exceptional accuracy (±0.1%). With its compact 18mm DIN rail design and wide operating voltage range (12-240V AC/DC), the FCT18-AdR is the optimal solution for demanding applications requiring precise retriggerable timing control.

Key Technical Advantages

Universal Voltage Input

Operates with 12-240V AC/DC, compatible with global industrial power standards.

Dual Timing Sequence

Precise control of T1 (On-Delay) and T2 (Output Duration) timing periods.

Ultra-Compact Design

Space-saving 18mm width (90×18×64mm) for high-density control panels.

Exceptional Accuracy

Repeat accuracy ∆< ±0.5% and Time setting accuracy ∆< ±0.1%.

Industrial Robustness

Designed for -20°C to +60°C environments with EMI resistance.

Retrigger Functionality

Supports retrigger during operation with each new control signal.

High-Capacity Output

16A C/O contacts (1 or 2 sets) for industrial loads.

EMI Resistance

Strong resistance to electromagnetic interference for reliable operation in industrial environments.

Button Setting & Locking

Precision time setting via tactile buttons with locking protection to prevent accidental changes.

Industrial Application Scenarios

The FCT18-AdR on-delay relay with retrigger functionality excels in scenarios where controlled sequences with restart capability are critical. Below are key applications where its advanced functionality delivers superior performance:

Retriggerable Process Control

Controls manufacturing processes where new input signals can restart timing sequences without interrupting operations.

Key Benefits:

  • Maintains process continuity during unexpected interruptions
  • Reduces downtime by eliminating full reset requirements
  • Increases production efficiency with flexible timing

Assembly Line Sequencing

Coordinates multi-stage assembly operations with precise timing and restart capability for each station.

Key Benefits:

  • Enables flexible production scheduling
  • Reduces jams and bottlenecks with intelligent timing
  • Retrigger function handles variable workpieces

Irrigation Systems

Manages watering cycles with programmable delays and restart capability based on sensor inputs.

Key Benefits:

  • Optimizes water usage with precise timing control
  • Automatically restarts cycles after interruptions
  • Reduces pump wear with soft-start functionality

Traffic Control Systems

Controls signal sequences with restart capability to handle varying traffic patterns and emergency vehicles.

Key Benefits:

  • Adapts timing to real-time traffic conditions
  • Prioritizes emergency vehicle passage
  • Reduces congestion with intelligent sequencing

HVAC System Control

Manages compressor and fan sequencing with restart capability after power fluctuations.

Key Benefits:

  • Protects equipment from rapid cycling
  • Reduces energy consumption with optimized timing
  • Automatically resumes operation after interruptions

Robotic Workcell Control

Synchronizes robotic operations with precise timing sequences and restart capability for error recovery.

Key Benefits:

  • Enables complex multi-stage robotic operations
  • Automatically recovers from interruptions
  • Improves production efficiency with flexible timing

Timing Sequence

fct18-adr-function-diagram

Timing Operation:

Control signal (S) applied – timing period T1 starts.

After preset time T1 – output (R) closes.

Output (R) remains closed for preset time T2.

After time T2 – output (R) opens.

Output (R) remains open until next control signal (S) is applied, which retriggers the sequence.

Wiring

fct18-adr-wiring-diagram

Connection Guide:

Standard DIN rail mounting with screw terminals for secure industrial connections:

  • A1/A2: Power supply terminals
  • S: Control signal input
  • 11/12/14 & 21/22/24: Output contacts (C/O)

Parameter Setting

timing-setting-diagram

Time Adjustment Protocol:

1
To set new parameters, press and hold the button until the LED starts flashing.
2
Press the button to switch between T1 and T2 settings. Adjust each time value by pressing and holding the button until the desired value is reached.
3
Press and hold the button until the LED stops flashing to save settings.
4
For the newly set parameters to take effect, you need to power off the device and then restart it.

Technical Specifications

Parameter FCT18-AdR1 FCT18-AdR2
Input terminal A1-A2
Voltage range AC230V / DC24V / ACDC12-240V
Voltage tolerance -15% ~ +10%
Output type 1 C/O contact 2 C/O contacts
Rated current 1×16A 2×16A
Power consumption AC 3.5VA / DC 2.0W
Time delay setting accuracy ±0.1% of full-scale value
Repeat accuracy Δt < ±0.5%
Mechanical life 10 million operations
Electrical life 100,000 operations
Ambient temperature -20°C to +60°C
Mounting DIN rail EN/IEC 60715
IP rating IP20
Dimensions 90×18×64mm
Standards IEC60947-5-1, EN6812-1
IEC 60947-5-1 Compliant
CE Certified
RoHS Compliant
IP20 Protection

Get Technical Support

Contact our engineering team for application assistance

fct18-adr-naming-convention

                CE                                                  Rohs                                                   EAC

Get A Quote