FCT18-AkR

on-delay relay with retrigger/restart control signal
Fct18-AkR
Products Categories
Get a quote
FCT18-Akr | On-Delay Time Relay with Retrigger Control | Fiicco Electrical

FCT18-Akr Industrial On-Delay Relay

Precision Timing Control with Retrigger Control Signal Functionality

Model: FCT18-Akr Series | DIN Rail Mount

Product Overview

The FCT18-Akr is a high-precision power on-delay relay with retrigger/restart control signal functionality. Engineered for industrial automation and control systems, it provides reliable timing control with exceptional accuracy (±0.1%) and durability. Featuring retrigger capability that allows restarting the timing cycle during operation, this relay is ideal for applications requiring dynamic control adjustments. With its compact 18mm DIN rail design and wide operating voltage range (12-240V AC/DC), the FCT18-Akr is the optimal solution for demanding industrial applications requiring precise timing control.

Key Technical Advantages

Universal Voltage Input

Operates with 12-240V AC/DC, compatible with global industrial power standards.

Extensive Timing Range

Precise timing from 0.1 seconds to 100 days for diverse industrial applications.

Ultra-Compact Design

Space-saving 18mm width (90×18×64mm) for high-density control panels.

Exceptional Accuracy

Repeat accuracy ∆< ±0.5% and Time setting accuracy ∆< ±0.1%.

Industrial Robustness

Designed for -20°C to +60°C environments with EMI resistance.

Retrigger Functionality

Control signal can restart the timing cycle at any time during operation.

High-Capacity Output

16A C/O contacts (1 or 2 sets) for industrial loads.

EMI Resistance

Strong resistance to electromagnetic interference for reliable operation in industrial environments.

Button Setting & Locking

Precision time setting via tactile buttons with locking protection to prevent accidental changes.

Industrial Application Scenarios

The FCT18-Akr on-delay relay with retrigger functionality excels in scenarios requiring dynamic timing adjustments. Below are key applications where its functionality delivers superior performance:

Equipment Cooling Systems

Maintains cooling fans or pumps for a preset period after machinery shuts down, with retrigger capability to adapt to intermittent operation patterns.

Key Benefits:

  • Extends equipment lifespan by managing residual heat
  • Retrigger feature adapts to intermittent operation
  • Reduces energy waste vs. continuous cooling

Safety Lighting Control

Delays shutdown of emergency lighting after main power cutoff, with retrigger functionality to reset timing during brief power fluctuations.

Key Benefits:

  • Ensures continuous safety lighting during transitions
  • Retrigger function maintains operation during brief outages
  • Compliant with industrial safety standards

Emergency Stop Sequences

Controls delayed deactivation of auxiliary systems after an emergency stop, with retrigger capability for staged shutdown sequences.

Key Benefits:

  • Mitigates mechanical stress during emergency shutdowns
  • Retriggering allows safe system restart without full reset
  • Improves overall safety protocol compliance

Fluid System Purge Cycles

Maintains valve actuation for a set period after pump shutdown, with retrigger functionality to extend purge cycles when needed.

Key Benefits:

  • Prevents fluid stagnation and system blockages
  • Adapts to variable operation via retriggering
  • Reduces maintenance costs from system fouling

Access Control Systems

Delays locking of industrial gates/doors after access authorization ends, with retrigger capability to extend access periods dynamically.

Key Benefits:

  • Prevents entrapment during access transitions
  • Retrigger feature accommodates extended access needs
  • Integrates seamlessly with security systems

Automated Process Control

Coordinates staged startup of production line components with retrigger capability to adapt to process variations.

Key Benefits:

  • Ensures process integrity during startup sequences
  • Retrigger adapts to unexpected process variations
  • Reduces downtime from sequence adjustments

Timing Sequence

fct18-akr-function-diagram

Timing Operation:

1. Control signal (S) applied – timing period T starts

2. After preset time (T) – output (R) closes

3. Output (R) remains closed as long as control signal (S) is present

Retrigger Function:

During the timing period T, if the control signal (S) is cycled (removed and reapplied), the timing restarts from zero.

Wiring

fct18-akr-wiring-diagram

Connection Guide:

Standard DIN rail mounting with screw terminals for secure industrial connections:

  • A1/A2: Power supply terminals
  • S: Control signal input
  • 11/12/14 & 21/22/24: Output contacts (C/O)

Note: Ensure proper grounding and follow local electrical codes for installation.

Parameter Setting

time-setting-diagram

Time Adjustment Protocol:

1
To set new parameters, press and hold the button until the LED starts flashing.
2
Adjust the parameters to desired values via the button.
3
Press and hold the button until the LED stops flashing.
4
For the newly set parameters to take effect, you need to power off the device and then restart it.

Technical Specifications

Parameter FCT18-Akr1 FCT18-Akr2
Input terminal A1-A2
Voltage range AC230V / DC24V / ACDC12-240V
Voltage tolerance -15% ~ +10%
Output type 1 C/O contact 2 C/O contacts
Rated current 1×16A 2×16A
Power consumption AC 3.5VA / DC 2.0W
Time delay setting accuracy ±0.1% of full-scale value
Repeat accuracy Δt < ±0.5%
Mechanical life 10 million operations
Electrical life 100,000 operations
Ambient temperature -20°C to +60°C
Mounting DIN rail EN/IEC 60715
IP rating IP20
Dimensions 90×18×64mm
Standards IEC60947-5-1, EN6812-1
IEC 60947-5-1 Compliant
CE Certified
RoHS Compliant
IP20 Protection

Get Technical Support

Contact our engineering team for application assistance

fct18-akr-naming-convention

                CE                                                  Rohs                                                   EAC

Get A Quote