FCT18-At

Power on-delay relay with retrigger/restart control signal and a instantaneous output relay
FCT18-At on delay time relay
Products Categories
Get a quote
FCT18-At | Dual Output Time Relay | Fiicco Electrical

FCT18-At Dual Output Time Relay

On-Delay Timing + Instantaneous Output in a Single Compact Unit

Model: FCT18-At Series | DIN Rail Mount

Product Overview

The FCT18-At is an advanced dual-output time relay featuring both on-delay timing and instantaneous output functionality. Engineered for industrial automation and control systems, it provides two independent 16A relay outputs – one with precise timing control and one with immediate response. With its compact 18mm DIN rail design and wide operating voltage range (12-240V AC/DC), the FCT18-At is the optimal solution for applications requiring both immediate and delayed control signals.

Dual Independent Output Design

The FCT18-At features two completely independent 16A relay outputs, providing both instantaneous and delayed control signals from a single device.

On-Delay Output

Provides precise timing control with adjustable delay from 0.1 seconds to 100 days after power-on.

Instantaneous Output

Immediately energizes upon power application and de-energizes immediately upon power removal.

Key Technical Advantages

Universal Voltage Input

Operates with 12-240V AC/DC, compatible with global industrial power standards.

Extensive Timing Range

Precise timing from 0.1 seconds to 100 days for diverse industrial applications.

Ultra-Compact Design

Space-saving 18mm width (90×18×64mm) for high-density control panels.

Exceptional Accuracy

Repeat accuracy ∆< ±0.5% and Time setting accuracy ∆< ±0.1%.

Industrial Robustness

Designed for -20°C to +60°C environments with EMI resistance.

Flexible Triggering

Supports NPN or PNP input options for versatile integration.

Dual High-Capacity Output

2×16A C/O contacts (1 delayed + 1 instantaneous) for industrial loads.

Button Setting & Locking

Precision time setting via tactile buttons with locking protection to prevent accidental changes.

Industrial Application Scenarios

The FCT18-At dual-output timer excels in scenarios where both immediate and delayed control actions are required. Below are key applications where its dual functionality delivers superior performance:

Motor Control Systems

Instant output controls main motor contactor while delayed output manages cooling fan operation after motor shutdown.

Key Benefits:

  • Immediate motor start with delayed cooling
  • Single device replaces two separate relays
  • Reduces panel space and wiring complexity

Lighting Control Systems

Instant output controls primary lighting while delayed output manages emergency or safety lighting after power loss.

Key Benefits:

  • Immediate illumination with delayed safety lighting
  • Simplifies lighting control circuits
  • Compliant with safety standards

Conveyor System Sequencing

Instant output starts primary conveyor while delayed output activates downstream equipment after precise time interval.

Key Benefits:

  • Eliminates multiple timing devices
  • Ensures proper material flow sequencing
  • Reduces jams and improves efficiency

Pump Control Systems

Instant output controls main pump operation while delayed output manages purge or drain cycles after pump shutdown.

Key Benefits:

  • Immediate pumping action with delayed purging
  • Prevents system blockages and corrosion
  • Reduces maintenance requirements

Heating Systems

Instant output activates heating elements while delayed output controls cooling fans after heating cycle completion.

Key Benefits:

  • Precise temperature control with safety cooling
  • Prevents overheating damage
  • Improves system longevity

Automated Machinery

Instant output controls primary machine functions while delayed output manages safety interlocks or indicator lights.

Key Benefits:

  • Enhanced machine safety with delayed indicators
  • Simplifies control cabinet wiring
  • Reduces component count and costs

Timing Sequence

fct18-at function-diagram

Dual Output Operation:

Instantaneous Output(R1) : Closes immediately upon power application and opens immediately upon power removal.

Delayed Output(R2) : The timing period T starts on power-on. At the end of the timing period T, the output closes.

Closing of the S contact makes the delayed output open. Opening of S restarts timing period T.

Wiring Diagram

fct18-at wiring diagram

Connection Guide:

Standard DIN rail mounting with screw terminals for secure industrial connections:

  • A1/A2: Power supply terminals
  • S: Control signal input
  • 11/12/14: Instantaneous output contacts (C/O)
  • 21/22/24: Delayed output contacts (C/O)

Parameter Setting

fct18-at time setting diagram

Time Adjustment Protocol:

1
To set new parameters, press and hold the button until the LED starts flashing.
2
Adjusting the parameters to desired values via press the button.
3
Press and hold the button until the LED stops flashing.
4
For the newly set parameters to take effect, you need to power off the device and then restart it.

Technical Specifications

Parameter FCT18-At
Input terminal A1-A2
Voltage range AC230V / DC24V / ACDC12-240V
Voltage tolerance -15% ~ +10%
Output type 2 C/O contacts (1 instantaneous + 1 delayed)
Rated current 2×16A (each contact)
Power consumption AC 3.5VA / DC 2.0W
Time delay setting accuracy ±0.1% of full-scale value
Repeat accuracy Δt < ±0.5%
Mechanical life 10 million operations
Electrical life 100,000 operations
Ambient temperature -20°C to +60°C
Mounting DIN rail EN/IEC 60715
IP rating IP20
Dimensions 90×18×64mm
Standards IEC60947-5-1, EN6812-1
IEC 60947-5-1 Compliant
CE Certified
RoHS Compliant
IP20 Protection

Get Technical Support

Contact our engineering team for application assistance

                CE                                                  Rohs                                                   EAC