FIICCO FCC18-01 Single-Phase Over-Current Protection Relay
FIICCO Industrial Relay

FCC18-01

Single-Phase Over-Current Protection Relay with Adjustable Reset Mode

Manual/Auto Reset Mode
AC/DC Wide Range
16A Contact
0.05-16A Current Range
18mm DIN Rail
CE Certified
RoHS Compliant
IEC 60947-5-1
GB/T 14048.5
EN 61812-1

Precision Over-Current Protection in 18mm

The FCC18-01 is a single-phase over-current protection relay designed to protect equipment from damaging over-current conditions. After power-on, the relay begins monitoring current after the configurable startup delay (Tr). If current exceeds the set threshold (I>), the relay trips after the time delay (Tt).

The FCC18-01 offers both manual and automatic reset modes — choose manual reset for applications requiring operator acknowledgment, or automatic reset for unattended systems where the load should restart once current returns to safe levels.

Key Advantage: The FCC18-01 supports both AC and DC current monitoring across 12 models covering 0.05A to 16A. With configurable time delays and selectable reset modes, it provides flexible over-current protection for virtually any single-phase application.

Quick Specifications

Supply Voltage AC/DC 12-240V
Current Range 0.05A - 16A
Reset Mode Manual / Auto (selectable)
Auto Reset I < 95% × I>
Time Delays Tr / Tt Adjustable
Output Contact 1 × SPDT (NO+NC)
Rated Current 16A / 250V AC
Mechanical Life 1 × 10⁷ operations
Electrical Life 1 × 10⁵ operations
Mounting DIN Rail EN/IEC 60715
Dimensions 90 × 18 × 64 mm

Why Choose the FCC18-01?

Engineered for industrial reliability and precise single-phase current monitoring.

Over-Current Protection

Monitors single-phase current and trips when current exceeds the adjustable threshold, protecting equipment from overload damage.

Manual / Auto Reset

Selectable reset modes: manual reset requires power cycle; auto reset activates when current drops below 95% of set value.

16A SPDT Output Relay

High-capacity SPDT output handles direct load switching. Mechanical life 10 million cycles, electrical life 100,000 cycles.

Tool-Free Configuration

Four front-panel button (I>, Tr, Tt, Mode) allow fast, screwdriver-free setup. No programming or software tools required.

AC & DC Compatible

Available in both AC and DC current monitoring models, covering 0.05A to 16A for versatile applications.

Over-Current Functions

Understanding manual and automatic reset modes for your application.

The FCC18-01 monitors single-phase current and provides over-current protection with configurable time delays. After power-on, the relay waits for the startup delay (Tr) before beginning current monitoring. If the measured current exceeds the set threshold (I>), the relay trips after the trip delay (Tt).

Choose the reset mode that matches your application requirements: Manual Reset requires a power cycle to restore operation (recommended for equipment requiring inspection after overload), while Automatic Reset restores power when current drops below 95% of the set threshold.

FCC18-01 Manual Reset Over-Current Protection
FCC18-01 - Over-Current Protection Function Diagram
FCC18-01 Manual Reset Mode

Manual Reset Mode

In manual reset mode, when current exceeds the set threshold (I>) for longer than the trip delay (Tt), the relay trips and opens the output contact. The relay remains tripped until power is cycled — this ensures that an operator must acknowledge the fault and inspect the system before restoring power.

  • Trip: When I > I> for Tt duration
  • Reset: Power cycle required (turn off, then on)
  • Ideal for: Equipment requiring inspection after overload
FCC18-01 Auto Reset Mode

Automatic Reset Mode

In automatic reset mode, when current exceeds the set threshold (I>) for longer than the trip delay (Tt), the relay trips. The relay automatically resets when the current drops below 95% of the set threshold (I < 95% × I>). This allows the load to automatically restart when the fault condition clears.

  • Trip: When I > I> for Tt duration
  • Reset: Automatic when I < 95% × I>
  • Ideal for: Unattended systems, remote locations

Technical Specifications

Full electrical and mechanical specifications for the FCC18-01 series.

Parameter Specification
Supply Voltage AC/DC 12-240V
Power Consumption AC 3.5VA / DC 2.0W
Voltage Tolerance -15% to +10%
Supply Indication Green LED (Un)
Relay Indication Red LED (R)
Current Setting Front Panel Button
Current Monitoring Range See model codes below
Startup Delay (Tr) Adjustable via dial
Trip Delay (Tt) Adjustable via dial
Auto Reset Threshold 95% × I> (fixed)
Output Contact 1 × SPDT (NO+NC)
Rated Current 16A / 250V AC
Mechanical Life 1 × 10⁷ operations
Electrical Life 1 × 10⁵ operations
Ambient Temperature -20°C to +60°C
Mounting DIN Rail EN/IEC 60715 (35mm)
Dimensions (H × W × D) 90 × 18 × 64 mm
Weight 68g
IP Rating IP20
Stripping Length 7mm (AWG13-20)
Torque Specification 0.4 N·m
Standards GB/T 14048.5, IEC 60947-5-1, EN 61812-1

* Storage temperature: -40°C to +85°C. Operating altitude: ≤2200m. Pollution level: 2.

Terminal Connections

SPDT relay output with screw-clamp terminals for fast, reliable wiring.

FCC18-01 — Single-Phase AC/DC Current Monitoring

A1
Power supply input (AC L / DC +)
A2
Power supply neutral (AC N / DC −)
11
Relay Common (C)
12
Relay Normally Closed (NC)
14
Relay Normally Open (NO)
S1
Monitored voltage input (AC L for AC models / DC+ for DC models)
S2
Load connection
Wiring Safety Checklist
  • Always de-energize the panel before wiring
  • Verify supply voltage matches the module rating before powering on
  • Wire the monitored load in series with the relay output circuit
  • Terminal 11 = Common, 12 = NC, 14 = NO — wire your load to the appropriate contact
  • Use correct wire gauge for 16A load current (min. 1.5mm²)
  • Tighten terminal screws to 0.4 N·m torque specification
  • Stripping length: 7mm (AWG13-20)

Front Panel & Settings

Configure the FCC18-01 using four adjustment button — no software or programming tools required.

Parameter Description Setting Range
I> Over-Current Trip Threshold — current above which the relay trips Model-specific, see ordering table
Tr Startup Delay — time after power-on before monitoring begins Adjustable via dial
Tt Trip Delay — time current must exceed threshold before trip Adjustable via dial
Mode Reset Mode — select manual or automatic reset Manual / Auto (selectable)

LED Indicator Panel

Un — Green LED

Lit = relay is powered on and monitoring the system

R — Red LED

Lit = NO contact (terminals 11-14) is closed, relay is energized

How to Set Parameters

  1. Enter setting mode: Press and hold the button until the LED starts flashing.
  2. Adjust dials: Set I>, Tr, Tt, and select reset mode to your desired values while the LED is flashing.
  3. Confirm: Press and hold the button until the LED stops flashing to save your settings.

Note: In auto reset mode, the relay will automatically close when current drops below 95% of the set threshold (I>). In manual reset mode, power must be cycled to restore operation after a trip.

Models & Ordering

Choose the current monitoring range that matches your application.

Model Code Voltage Type Current Range Typical Applications Manual
FCC18-01-A0.5 AC 0.05 - 0.5A AC Low-power AC circuits, control circuits PDF ↓
FCC18-01-A1 AC 0.1 - 1A AC Small motors, lighting circuits PDF ↓
FCC18-01-A2 AC 0.2 - 2A AC Medium motors, HVAC equipment PDF ↓
FCC18-01-A5 AC 0.5 - 5A AC Large motors, industrial equipment PDF ↓
FCC18-01-A8 AC 0.8 - 8A AC Heavy motors, industrial machinery PDF ↓
FCC18-01-A16 AC 1.6 - 16A AC High-power equipment, industrial panels PDF ↓
FCC18-01-D0.5 DC 0.05 - 0.5A DC Low-power DC circuits, telecom PDF ↓
FCC18-01-D1 DC 0.1 - 1A DC Small DC motors, battery systems PDF ↓
FCC18-01-D2 DC 0.2 - 2A DC Medium DC loads, solar systems PDF ↓
FCC18-01-D5 DC 0.5 - 5A DC Large DC motors, battery chargers PDF ↓
FCC18-01-D8 DC 0.8 - 8A DC Heavy DC loads, industrial DC PDF ↓
FCC18-01-D16 DC 1.6 - 16A DC High-power DC equipment PDF ↓
* Reset mode (Manual/Auto) can be configured via front panel button. Other current ranges available on request. Contact FIICCO at info@fiicco.com or via WhatsApp for custom configurations, OEM branding, and volume pricing.

FCC18 Family — Model Comparison

Compare the FCC18 series current relays to find the right protection configuration for your application.

Model Over-Current Under-Current Reset Mode Voltage Type Ideal For
FCC18-01 Adjustable Manual / Auto AC / DC Over-current protection with selectable reset mode for flexible applications
FCC18-02 Adjustable Manual / Auto AC / DC Under-current protection (e.g., no-load detection) with selectable reset mode
FCC18-03 Adjustable Adjustable Manual Only AC / DC Over and under-current protection, manual reset ensures operator acknowledgment
FCC18-04 Adjustable Adjustable Auto Only AC / DC Over and under-current protection, automatic restart when conditions normalize

Configuration Examples

Real-world setting examples for common current systems.

FCC18-01-A2 — 1A AC Motor

AC 1A Motor Protection
Over-current (I>) 1.2A
Startup Delay (Tr) 2s
Trip Delay (Tt) 0.5s
Reset Mode Manual

FCC18-01-A5 — 3A AC System

AC 3A Equipment Protection
Over-current (I>) 3.5A
Startup Delay (Tr) 3s
Trip Delay (Tt) 1s
Reset Mode Auto

FCC18-01-D2 — 1A DC System

DC 1A Battery System
Over-current (I>) 1.2A
Startup Delay (Tr) 1s
Trip Delay (Tt) 0.5s
Reset Mode Auto

FCC18-01-D8 — 5A DC System

DC 5A Solar System
Over-current (I>) 6A
Startup Delay (Tr) 5s
Trip Delay (Tt) 2s
Reset Mode Manual

See It In Action

Watch the FCC18-01 product overview and demonstration.

Typical Applications

The FCC18-01 protects equipment across a wide range of industrial sectors.

Motor Protection

Protect single-phase motors from overload damage and winding failures.

Solar Installations

Protect DC solar inverters and battery storage systems from over-current.

Telecom Power

Protect telecom base station power systems and DC distribution equipment.

Battery Systems

Protect 12V/24V/48V battery banks from over-current damage.

Industrial Control

Protect PLCs, sensors, and control circuits from over-current faults.

Ready to Order or Need More Details?

Download the full technical manual or contact the FIICCO team for pricing, samples, and OEM options.

Frequently Asked Questions

Common questions about the FCC18-01 single-phase over-current protection relay

Manual Reset: When the relay trips due to over-current, it remains in the tripped state until power is cycled (turned off and on again). This is recommended for equipment that requires operator inspection after an overload event. Automatic Reset: When current drops below 95% of the set threshold (I < 95% × I>), the relay automatically resets and restores power to the load. This is ideal for unattended systems.

The FCC18-01 series offers 12 models: AC models (A0.5: 0.05-0.5A, A1: 0.1-1A, A2: 0.2-2A, A5: 0.5-5A, A8: 0.8-8A, A16: 1.6-16A) and DC models (D0.5: 0.05-0.5A, D1: 0.1-1A, D2: 0.2-2A, D5: 0.5-5A, D8: 0.8-8A, D16: 1.6-16A).

Tr (Startup Delay): After power-on, the relay waits for Tr seconds before beginning current monitoring. This prevents nuisance trips during motor startup when high inrush current is normal. Tt (Trip Delay): Once current exceeds the set threshold (I>), the relay must remain in this condition for Tt seconds before tripping. This filters out brief current spikes that don't represent a true overload condition.

Yes. The FCC18-01 is available in both AC and DC versions. AC models (A-series) monitor alternating current systems, while DC models (D-series) monitor direct current systems such as batteries, solar installations, and DC power supplies. All models can be powered by AC/DC 12-240V supply.

The FCC18-01 has a single SPDT (single-pole double-throw) relay contact rated 16A/250V AC. Terminal 11 is the common, 12 is normally closed (NC), and 14 is normally open (NO). Wire your load between terminal 11 and terminal 14 for normally open operation — the circuit is energized when the relay is in the normal (non-tripped) state.

In automatic reset mode, the relay resets when the monitored current drops below 95% of the set over-current threshold (I>). For example, if I> is set to 10A, the relay will automatically reset when current falls below 9.5A (10A × 95%). This prevents rapid on/off cycling when current hovers near the threshold.

The FCC18-01 is certified to CE, RoHS, and meets the standards of IEC 60947-5-1, GB/T 14048.5, and EN 61812-1. This makes it suitable for industrial automation applications in Europe, Asia, and other global markets.

Yes. FIICCO provides OEM services including custom branding (logo, model number, color), tailored specifications, and custom packaging for orders of 100+ units. Factory-direct pricing ensures competitive costs for OEM customers. Contact us at info@fiicco.com with your requirements and quantity for a tailored quotation.

Get A Quote