Flashing Time Relay
with Independently Adjustable T1 & T2
Industrial-grade symmetrical/asymmetrical flasher with digital setting, ultra-wide voltage range, and flexible start mode selection via control signal.
📋 Models & Ordering
| Model | Supply Voltage | Output Contact | Control Terminal | Start Mode | Datasheet |
|---|---|---|---|---|---|
| FCT18-S1W | 12–240V AC/DC | 1 × SPDT | S (Control) | S open: Start ON / S–A1: Start OFF | 📄 Download PDF |
| FCT18-S2W | 12–240V AC/DC | 2 × SPDT | S (Control) | S open: Start ON / S–A1: Start OFF | 📄 Download PDF |
💡 Control Signal S: When S is open (not connected), the output starts with ON state. When S is connected to A1, the output starts with OFF state, allowing flexible integration into different control schemes.
⚙️ Technical Specifications
🔌 Input
| Input Terminal | A1 – A2 |
| Supply Voltage | 12–240V AC/DC |
| Power Consumption | AC 3.5VA / DC 2.0W |
| Voltage Tolerance | -15% ~ +10% |
🎛️ Time Circuit
| Function | Flashing (symmetrical / asymmetrical) |
| Time Range T1, T2 | 0.1s – 100 days (each independently) |
| Time Setting | Button (digital) |
| Time Deviation | 0% – Digital Setting |
| Repeat Accuracy | 0.2% |
| Temperature Coefficient | 0.01%/°C (at 20°C) |
🔌 Output
| Contact (S1W) | 1 × SPDT |
| Contact (S2W) | 2 × SPDT |
| Rated Current | 16A @ 250V AC |
| Mechanical Life | 1×10⁷ operations |
| Electrical Life | 1×10⁵ operations |
📐 Physical & Environmental
| Dimensions | 18 × 90 × 64 mm |
| Mounting | DIN rail EN 60715 |
| Protection Degree | IP40 (front) / IP10 (terminals) |
| Operating Temp. | -20°C ~ +55°C |
| Storage Temp. | -30°C ~ +70°C |
📜 Standards & Certifications
| Compliance | GB/T 14048.5, IEC 60947-5-1, EN 6812-1 |
| Contact Configuration | SPDT: 11(COM)-12(NC)-14(NO) 2nd pole: 21(COM)-22(NC)-24(NO) |
| Pollution Degree | 2 |
| Max. Cable Size | AWG 13–20 / 0.4 N·m |
📈 Function Diagram – Flashing Operation & Start Mode
• After power-on, a repetitive cycle consisting of two independently adjustable timing periods T1 and T2 starts.
• Each timing period corresponds to a different state of the output R (ON/OFF). This cycle is repeated indefinitely until the power supply is removed.
• Start Mode Selection via Terminal S:
– When control signal S is not applied (open), the cycle starts with R ON (T1 ON, then T2 OFF).
– When control signal S is applied (connected to A1), the cycle starts with R OFF (T1 OFF, then T2 ON).
• Adjust T1 and T2 to create symmetrical or asymmetrical flashing patterns as required.
🎬 See it in Action
🔧 Wiring & Terminal Layout
Terminal Identification
Start ON: Leave terminal S open (no connection). Output starts in ON state (relay energized).
Start OFF: Connect S to A1. Output starts in OFF state (relay de-energized).
🛠️ Parameter Setting Guide
- Enter Parameter Setting Mode: Press and hold the button until the LED starts flashing. This indicates you have entered the configuration mode.
-
Adjust T1 & T2: Set the desired time range and fine time for both T1 and T2 independently using the button. The scale markings on the front panel guide your setting.
💡 Note: When the green LED is ON during time range setting, add +5% to the value indicated on the scale for accurate timing.
- Confirm New Parameters: After adjusting to your desired values, press and hold the button until the LED stops flashing. The new parameters are now stored.
- Make Parameters Effective: After confirming parameters, you must power off and restart the device to activate the new settings.
🏭 Typical Applications
Flashing beacon control for safety and status indication
Intermittent audible/visual alarm activation
Alternating operation of pumps or compressors
Intermittent fan operation for humidity and temperature management
Repeating on-off cycles for conveyor or feeder systems
Generating periodic test signals for PLC inputs